Construction :
Cable lay up : 4 pairs to the core, non-metallic cross separator (spline).
Migration and water protection.
Sheath: White , LSZH or PVC
Application:
-Primary (Campus), Secondary (Riser), Tertiary (Horizontal)
-IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;
-IEEE 802.5 16 MB; ISDN; TPDDI; ATM
-IEEE 802.3af-2002: POE; IEEE 802.3at: POE+
-Outdoor installations. Filled with compound to prevent water penetration.
-To ensure electrical properties even in continuous wet conditions.
Standards: ISO/IEC 11801.; EN 50288-6-1;IEC 61156-5 EN 50173-1,
Water penetration rating : IEC 60794-1-2F5 , method B
Fire rating : (PE outer sheath) IEC 60754-2; Smoke classi cation: No
Technical Data :
Cable designation: Industry U/UTP Cat.6 500MHz 4PxAWG23
Packaging : Drum 305
Outer diameter: Nominal 7.2 mm
Weight: 20 kg / km
Thermal load : 1884 MJ / km
Segregation class : b
Mechanical Properties :
Tensile force : 100 N
Bending radius :
≥ 33 mm during operation (without load)
≥ 65 mm during installation (with load)
Temperature range:
During operation -55°C…+ 60°C
During installation -15°C…+ 50°C
Electrical Properties (at 20°C ± 5°C)
DC loop residence: ≤ 17.6 Ω / 100 m
Resistance unbalance: ≤ 2 %
Test voltage: DC, 1 min, core/core 1000 V
Insulation resistance : 500 V ≥ 5000 MΩ * km
Capacitance: 48 pF / m nom.
Capacitance unbalance : ≤ 1500 pF / km
Mean characteristic impedance : 100 ± 5 Ω
Nominal velocity of propagation : Approx. 67 %
Propagation delay : At 1 MHz ≤ 535 ns / 100 m
Delay skew : ≤ 20 ns / 100 m
Coupling attenuation : ≥ 40 dB
Balance TCL :
At 1 MHz ≤ 55 Db-
At 10 MHz ≤ 40 dB
At 100 MHz ≤ 35 dB